HW R7284U-1004
Supplier Part #: R7284U1004/U
Oil Primary, Elec 15/30/45 Sec Lockout 2-Line LCD Display
Product Info
Oil Primary Controls
R7284 Interrupted Electronic Oil Primary Control
- Digital, universal primary control, engineered to address and anticipate
the most common industry needs - Provides line voltage, safety rated, interrupted and intermittent ignition
oil primary control for residential oil fired burners used in boilers,
forced air furnaces and water heaters - Used with a cad cell flame sensor operates an oil burner, spark igniter,
and optional oil valve - Every setting and diagnostic is user-friendly displayed and
available in multiple languages - Works with a low voltage and optional high voltage thermostat
- The primary controls fuel oil, senses flame, controls ignition spark
(either interrupted or intermittent) and notifies through the EnviraCOM
bus a remote alarm circuit when in lockout - Can be used with both hydronic and forced air systems
- When used with hydronic systems, line voltage switching Aquastat® Controllers
normally provide for the starting and stopping of the combustion sequences - With forced air systems, both mechanical and electronic low voltage thermostats
control the starting and stopping of the combustion process - Mounts in junction box on main burner
- Temperature range: -40° to 147°F (-40° to 64°C)
- Electrical connections: burner motor, oil valve, ignition, cad cell, limit, thermostat, alarm
- UL and cULus Listed
Item Specifications
-
44.4A
-
4-5/32" x 4-11/32" x 2-1/2"
-
15-Second
-
120V
-
1.50 lbs per EA